  specifications features data sheet fhn fcx ?c series the fcx? flow transmitter accurately measures differential pressure generated by a primary element, and transmits 4 to 20ma signal proportional to flow. the transmit- ter utilizes the unique micromachined capacitive silicon sen- sor with state-of-the-art microprocessor technology to pro- vide exceptional performance and functionality. 1. high accuracy 0.1% accuracy (for a range of 50% to 100% of flow) for all calibrated spans is the standard feature for all models covering 0.6kpa{6mbar} draft range to 2000kpa{20bar} high differential. fuji's micro-capacitance silicon sensor assures this feature. 2. minimum inventory electronics unit, communication module, local indicators and electronics housing are interchangeable among all fcx? models. process cover including bolts and nuts are common for all dp and flow transmitters, rating 3.2 and 14mpa (32 and 140bar). 3. upgradable electronics a small plug-in communication module (to be ordered separately) can upgrade your fhn flow transmitters to have remote communication functions. a hand held communicator (model fxw, consult data sheet no. eds8-47) can remotely display or reconfigure process values as well as all transmitter configuration parameters at any point on the loop without affecting the transmitter signal. 4. fuji/hart bilingual communication module the communication module is "bilingual" to speak both fuji proprietary protocol and hart. any hart compatible devices can communicate with fcx-a/c series trans- mitters. 5. application flexibility example features that render the fcx? suitable for almost any process applications includes: analog indicator at either the electronics side or ter- minal side full range of hazardous location approvals built-in rfi filter and lightning arrester ? -digits lcd meter functional specifications service: liquid, gas, or vapour static pressure, span, and range limit: type static pressure [mpa] {bar} range limit [kpa] {mbar} span limit [kpa] {mbar} max. min. ?.1 to + 3.2 {? to + 32 } ?.1 to + 14 {? to + 140 } ?.1 to + 14 {? to + 140 } ?.1 to + 14 {? to + 140 } ?.1 to + 14 {? to + 140 } fhn 12 fhn 33 fhn 35 fhn 36 fhn 37 0.6 {6} 3.2 {32} 13 { 130 } 50 { 500 } 200 { 2000 } 6 {60} 32 { 320 } 130 { 1300 } 500 { 5000 } 2000 { 20000 } +/ 6 { +/ 60 } +/ 32 { +/ 320 } +/ 130 { +/ 1300 } +/ 500 { +/ 5000 } +/ 2000 { +/ 20000 } lower limit of static pressure (vacuum limit) is; silicone fill sensor: see fig. 1 fluorinated fill sensor: 66kpa abs (500mmhg abs) at temperature below 80 c. the maximum span of each sensor can be converted to in different units using below factors. 1mpa=10 3 kpa=10bar= 10.19716kgf/cm 2 =145.0377psi 1kpa=10mbar=101.9716mmh 2 o=4.01463inh 2 o flow transmitter 1 2 date EDSX6-105 feb. 2, 1999
fhn 2 overrange limit: to maximum static pressure limit output signal: 4 to 20ma dc square root of differential input pressure between 0.5% and 100% of input. linear or zero is selectable below 0.5% of input. power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5 to 32v dc for the units with optional arrester. load limitations: see figure below loop-check output: transmitter can output constant signal of 4ma, 12ma, or 20ma if mode switch is set to the loop check mode. temperature limit: ambient: ?40 to + 85 c (?20 to + 80 c for lcd indicator) (?40 to + 60 c for arrester option) ( 10 to + 60 c for fluorinated oil fill transmitter) for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard. process: ?40 to +100 c for silicone fill sensor ?20 to +80 c for fluorinated oil fill sen- sor storage: ?40 to +90 c humidity limit: 0 to 100% rh performance specifications accuracy rating: (including conformity, hysteresis and re- peatability) 0.1% of calibrated span for a range of 50% to 100% of flow. ( 0.25% for a range of 20% to 50% of flow) stability: 0.2% of upper range limit (url) for 24 months (in case of 6th digit code "3", "5", "6", "7") temperature effect: effects per 28 c change between the lim- its of ?40 c and +85 c hazardous locations: note: for communication with fxw, min. of 250 ? required. baseefa ex ds iic t5, t6 eex ia iic t4, t5 ex n ii t5 factory class i ii iii class i ii iii class i ii iii mutual div. 1 div. 1 div. 2 groups b thru. g groups a thru. f groups a thru. g csa class i ii iii class i ii iii class i ii iii div. 1 div. 1 div. 2 groups c thru. g groups a thru. g groups a thru. g saa ex d ii c t5, t6 ex ia ii c t5, t6 ex n ii c t5, t6 ip 66/67 ip 66/67 ip 66/67 type n nonincendive authorities flameproof intrinsic safety range code (6th digit in "code symbols") ?? 6kpa {60mbar} max. span ?? 32kpa {320mbar} max. span ?? 130kpa {1300mbar} max. span ?? 500kpa {5000mbar} max. span ?? 2000kpa {20000mbar} max. span static pressure effect: shift at 20% output (% of url) static pressure code (5th digit in "code symbols") ??/ 6kpa {60mbar} sensor ? 1% / 3.2mpa{32bar} 0.5% / 10mpa{100bar} overrange effect: shift at 20% output (% of url) static pressure code (5th digit in "code symbols") ? ? 1% / 3.2mpa{32bar} 1% / 14mpa{140bar} shift at 20% output (% of url) shift at 20% output zero/span adjustment : zero is adjustable from an external adjust- able screw. the adjustable screw can also function to adjust span when mode switch (lo- cated on the electronics unit) is in the span mode. inhibit mode to disable the ad- justable screw is also available. damping: adjustable electrical damping. the time constant is adjustable to 0, 0.3, 1.2, 4.8, or 19.2 seconds. zero elevation/suppression: ?00% to +100% of url normal/reverse action: selectable by moving a jumper pin located on the electronics unit. indication: analog indicator or 4 -digit lcd meter, as specified. burnout direction: output hold output 21.6ma selectable output 3.8ma note: unless otherwise specified, the output is in hold position. } url span 2000 [ ? ] 1500 1000 load resistance 500 250 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage (0.625 )% / 28 c (0.25 )% / 28 c 1 2 url span
3 supply voltage effect: less than 0.05% of calibrated span per 10v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) step response: (without electrical damping) non-wetted parts material: electronics housing: low copper die-cast aluminum alloy (standard), finished with epoxy/polyurethane double coat- ing, as specified. bolts and nuts: cr-mo alloy (standard), 304 stainless steel, or 630 stainless steel. static pressure rating for code ??with 304 stainless steel bolts is degraded to 10mpa{100bar}. fill fluid: silicone oil (standard) or fluori- nated oil (daifloil) mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 4x mounting: on 60.5mm (jis 50a or 2b) pipe using mounting bracket, direct wall mounting, or direct process mounting. mass{weight}: transmitter approximately 3.4kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option optional features communication module: (not included in transmitter shipments. separate order by part no. zzpfcx2-a170 is required) the communication module, that can be pluged-in on the transmitter electronics, provides bidirectional communication with the hand held communicator. (model fxw, consult data sheet eds 8-47.). the information that can be remotely display- ed or reconfigured is as follows. dead time approx. 0.3 s type fhn 12 fhn 33 fhn 35 to 37 time constant 0.85 s 0.45 s 0.2 s mounting position effect: zero shift, less than 0.12kpa {1.2mbar} for a 10 tilt in any plane. no effect on span. this error can be corrected by adjusting zero. (double the effect for fluorinated fill sen- sors) dielectric strength: 500v ac, 50/60hz, 1 min., between circuit and earth. insulation resistance: more than 100m ? at 500v dc. turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less physical specifications electrical connections: g1/2, 1/2-14 npt, pg13.5, or m20 x 1.5 conduit, as specified. process connections: 1/4-18 npt or rc1/4 on 54mm centers, as specified. meets din 19213. process-wetted parts material: v 316 stainless steel 316 stainless steel 316l stainless steel 316 stainless steel (* 1 ) material code (7th figure in "code symbols") process cover diaphragm wetted sensor body vent/drain note: * (1) scs 14 per jis g 5121 remark: sensor o-rings: viton or teflon selectable tag no. model no. serial no. engineering unit range limit measuring range damping output mode burnout direction adjustment output adjust data self diagnoses printer external switch lock transmitter display(*) vv vv v vv v vv vv vv vv vv ? v v vv vv items display set note: (*) hhc's version must be more than 5.0 (or fxw 1? 2), to use this function.
fhn 4 accessories indicator: a plug-in turnable analog indicator (1.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. an optional 4 digits lcd meter is also available. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 50 s) oxygen service: special cleaning procedures are followed throughout the process to maintain all pro- cess wetted parts oil-free. the fill fluid is fluorinated oil. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use for oxygen or chlorine measurement. nace specification: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. astm b7m or l7m bolts and 2hm nuts (class ii) are available. static pressure rating for code ? (14mpa {140bar}) is degraded to 10mpa {100bar}. oval flanges: (model ffp, refer to data sheet no. eds6-10) converts process connection to 1/2-14 npt or to rc1/2; in carbon steel or in 316 stainless steel. three-value manifolds: (model ffn, refer to data sheet no. eds6-10) available in carbon steel or in 316 stain- less steel and in pressure rating 14mpa {140bar}. fig. 1 relation between process temperature and operating pressure customer tag: a stainless steel tag with customer tag data is wired to the transmitter. ?0 60 100 none-operating area 2.7 (20) 6.7 (50) 53.3 operating pressure process temperature[ c ] (400) 101 (760) [kpa abs] (mmhg abs) sealing liquid;silicone oil (code:y,g,n) operating area 1 2
5 description 1 f n 12345678 910111213 1415 type without communication module connections process conn. screw size for oval flange conduit conn. rc1/4 7/16-unf g 1/2 1/4-18npt 7/16-unf 1/2-14npt 1/4-18npt m10 or m12 pg 13.5 1/4-18npt m10 or m12 m20 x 1.5 1/4-18npt 7/16-unf pg13.5 span and materials indicator and arrester indicator arrester none none analog, 0 to 100% linear scale none analog, custom scale none analog, double scale none none yes analog, 0 to 100% linear scale yes analog, custom scale yes analog, double scale yes digital, 0 to 100% none digital, 0 to 100% yes approvals for hazardous locations none (for ordinary locations) fm, flameproof (or explosionproof) csa, flameproof (or explosionproof) ( available for 4th digit code "t") baseefa, flameproof (conduit seal) ( available for 4th digit code "t") baseefa, flameproof (cable gland seal) (conduit connection g 1/2 only) fm, intrinsic safety and nonincendive csa, intrinsic safety and nonincendive cenelec, intrinsic safety cenelec, intrinsic safety and baseefa, type n saa flameproof (conduit seal) ( available for 4th digit code "s, t, w") saa intrinsic safety ( available for 4th digit code "s, t, w") saa type ?n (non-speaking) ( available for 4th digit code "s, t, w") process connection side vent yes / no mounting bracket yes / no none none none yes (stainless steel) yes none yes yes (stainless steel) h s t v w x 12v 33v 35v 36v 37v static pressure [mpa] {bar} span limit [kpa] {mbar} material element diaphragm wetted cell body process cover ?.1 to +3.2 {? to +32} ?.1 to +14 {? to +140} 0.6? {6?0} 3.2?2 {32?20} 13?30 {130?300} 50?00 {500?000} 200?000 {2000?0000} 316 stainless steel(* 1 ) 316 stainless steel(* 1 ) 316 stainless steel(* 1 ) 316 stainless steel(* 1 ) 316 stainless steel(* 1 ) 316l stainless steel 316l stainless steel 316l stainless steel 316l stainless steel 316l stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel a b d j e f h k l q a d e m n h j k p r t q a c d f note: *( 1 ) scs14 per jis g 5121 code symbols
fhn 6 note : (2) static pressure should be ?0.1 to +10mpa{? to +100bar}. (3) available for the 5th digit code "1" or "3". in case of the 5th digit code "3", static pressure should be ?0.1 to +10mpa{? to +100bar}. (4) available for the 5th digit code "3". in case of 630 stainless steel bolt, static pressure should be ?0.1 to +14mpa{? to +140bar}. (5) in case of tropical use, select a stainless bolts and nuts. description 1 f n 12345678 910111213 1415 optional specification stainless tag none yes special applications and fill fluid treatment filled liquid none (standard) silicone oil degreasing silicone oil oxgen service fluorinated oil nace specification silicone oil o-ring materials viton teflon vent / drain plug type casing bolt / nut materials y b y g a n a b c d e f a b standard standard standard standard standard standard standard (cr-mo hex. socket head cap screw) cr-mo hexagon bolt / nut nace bolt / nut (astm a193 b7m/a194 2hn) nace bolt / nut (astm a320 l7m/a194 2hm) 304 / 304 stainless steel (* 3 ) 630 / 304 stainless steel (* 4 ) } } (* 2 ) (* 5 ) the product conforms to the requirements of the electromagnetic compatibility directive 89/336/eec as detailed within the technical construction file number tn510412. the applicable standards used to demonstrate compliance are :- emi (emission) en50081-1 : 1992 "lvd - the transmitter is not covered by the requirements of the lvd standard." ems (immunity) en50082-1 : 1992 test item frequency range basic standard applicable electro- magnetic radiation disturbance 30-1000mhz en55022 class b test item no. test specification basic standard performance criteria 1 2 3 b a b electrostatic discharge fast transients common mode 0.5kv, 5/50 (tr/th) ns 5khz rep. radio-frequency electromagnetic field. 8kv (air) 27-500mhz 3v/m (unmodulated) iec 801-2:1984 iec 801-3:1984 iec 801-4:1988
7 outline diagram (unit:mm) note *: cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. earth terminal m4 no. 8-32unc m4 m4 m4 oval flange screw 7/16-20unf screw depth 13 7/16-20unf screw depth 13 m10 or m12 screw depth 13 m10 or m12 screw depth 13 7/16-20unf screw depth 13 4th of code symbols s t v w x d g1/2 1/2-14npt pg13.5 m20x1.5 pg13.5 press. conn. g rc1/4 1/4-18npt 1/4-18npt 1/4-18npt 1/4-18npt conduit conn. e 17 16 8 16 8 f 8 5 4.5 5 4.5 table 1 fastener (flameproof ex. only) zero span adj. screw 104 80 120 45.5 126.5 "b" conduit conn. 4th of code symbol "s, v, w, x" type is attached u-bolt m8 "a" press. conn. mtg pipe jis 50a (2b) 4 holes 9 dia. vent/drain plug "c" conduit conn. *cable gland 110 50 88 70 193 30 58 38 up down earth terminal (both side) see table 1 higher pressure oval frange screw see table 1 lower pressure 51 71 (27) 80 221 41.3 54 70 120 details of "a" details of "b" details of "c" see table 1 see table 1 7 8 2.5 g 18.5 15 f e d 13 g1/2 17 with field ind. (option) s t v w x fhn v1 75 20 ck+ ck + + connection diagrams
fhn information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDSX6-105

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X